All products comply with ASTM F1545 Standard Specification for Plastic-Lined Ferrous Metal Pipe, Fittings, and
Flanges

All welds are in compliance with ASME B31.3 and welders are certified to Section IX of ASME Boiler and
Pressure Vessel Code.

Components are sand blasted and primed with Rust Preventive Gray Primer and suitable for top coating.
Special paint is available upon request

All Parts are subjected to a minimum of 10,000 volts to detect liner defects.  An audible or visible spark through
of the liner is cause for rejection.

All faces are protected by wooden end blocks, which shall remain in place until parts are to be installed
Manufacturer, ASTM F1545 designation and liner type are provided on the identification band located on the
part. Lettering shall read: JCS TOOL ASTM F1545 PTFE.  Parts are also metal stamped with liner tracing
number and identification on the flange when possible.

Polytetraflouroethylene (PTFE) Liner Requirements
   1.Tensile @ Yield             3000 psi min
   2.Elongation @ Yield        250% min
   3.Colorants                        0%

PTFE Operating Requirements
   PTFE Lined Parts can operate at: -20 degrees F.(-29 C) to 450 degrees F. (232 C)
   
PolyPropylene (PP) Liner Requirements
   1. Tensile @ Yield 4000 psi min
   2. Elongation @ Yield 10% min
   3. Colorants 1% max(Orange)

PP Operating Requirements
   Parts can operate at: -0 degrees F.(-18 C) to 225 degrees F. (107 C)

PolyVinyl(PVDF) Liner Requirements
   1. Tensile @ Yield 4500 psi min
   2. Elongation @ Yield 10% min
   3. Colorants 1% max(Black)

PVDF Operating Requirements
   Parts can operate at:  0 degrees F.(-18 C) to 275 degrees F. (135 C)